| Microcomputer |
|
Intel 16 bit running @ 16Mhz |
| Supply Voltage |
Normal operation
Safe limits
|
6.2V to 23V DC continuous
+/- 24V (5 min)
+/- 80V alternator load dump (0.5 sec).
+/- 1000V inductive spike (10 usec) |
| Current Drain |
@ Engine idle
@ Max Engine Load
|
< 1 Amp.
< 16 Amp (less depending on injector type
and number. |
Operating Temperature Range
|
Min
Max
|
- 40 deg C.
+ 85 deg C. |
| Engine Cylinder Number Settings |
Number of cylinders
|
1, 2, 3, 4, 5, 6,
7, 8, 10, 12, 14 and 16 |
| Engine RPM Range |
0 to 30,000 RPM
0 to 16,000 RPM
0 to 15,000 RPM
|
Engines up to 4 cylinders
Engines up to 5 to 8 cylinders.
Engines 10 to 16 cylinders. |
| Injection Duration Timing |
Min
Max
Accuracy
Setting resolution
|
0.7 msec.
30 msec.
+/- < (10 usec + 1%)
0.1% approx. |
| Injection Timing |
Range
Accuracy
Setting resolution
|
0 to 720 deg (crank angle).
+/- < (1.4 deg + 0.3 msec).
2.8 deg. |
| Ignition Timing |
Advance range
Accuracy
Setting resolution
|
0 to 45 deg (crank angle).
+/- 0.2 deg (crank angle).
0.5 deg (crank angle). |
| Fuel Delivery and Ignition Mapping |
No. Load sites
No. RPM sites
|
16 (max).
Both Load and RPM
sites
32 (max). are
freely selectable. |
| Size |
L * W * H
|
157 * 122 * 35 mm
180 * 128 * 35 mm (overall, including mounts
& connector) |
| Weight |
|
0.5 kg |
| Connectors |
|
36 way 'AMP' water and dust
proof socket |